| B100011 | medium | Output short-circuit to GND | Volvo TRUCKCIOM | power_supply | Открыть |
| B100012 | medium | Output short-circuit to BAT+. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100013 | medium | Open circuit conditions detected on output pin | Volvo TRUCKCIOM | power_supply | Открыть |
| B100016 | high | Feedback voltage measured on the output is lower defined threshold. Threshold: < Vbat - 2V. | Volvo TRUCKCIOM | aftertreatment | Открыть |
| B100017 | high | Feedback voltage measured on the output is higher defined threshold. Threshold: 5V. | Volvo TRUCKCIOM | aftertreatment | Открыть |
| B100111 | high | Input stay connected to GND more than defined time (P1DWC). | Volvo TRUCKCIOM | aftertreatment | Открыть |
| B100112 | medium | Resident voltage level in circuit when not expected by function. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100211 | high | Input stay connected to GND more than defined time (P1DWB). | Volvo TRUCKCIOM | aftertreatment | Открыть |
| B100212 | medium | Resident voltage level in circuit when not expected by function. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100311 | high | Output short-circuit to GND. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100312 | high | Output short-circuit to BAT+. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100313 | medium | Open circuit conditions detected on all 4 output pins. Threshold for open circuit detection: <1mA external current at output voltages between 10V and 14V. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100316 | high | Feedback voltage measured on the output is lower than 11,4V threshold (configurable). | Volvo TRUCKCIOM | power_supply | Открыть |
| B100317 | high | Feedback voltage measured on the output is higher 14V threshold (configurable). | Volvo TRUCKCIOM | power_supply | Открыть |
| B100411 | medium | Output short-circuit to GND. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100412 | medium | Output short-circuit to BAT+. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100413 | medium | Open circuit conditions detected on output pin. Threshold for open circuit detection: <100uA @ 0,8V. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100416 | high | Feedback voltage measured on the output is lower defined threshold (configurable). Threshold: <(0.1*VBAT)-0.2. | Volvo TRUCKCIOM | aftertreatment | Открыть |
| B100417 | high | Feedback voltage measured on the output is higher defined threshold (configurable). Threshold: <0.05*VBAT. | Volvo TRUCKCIOM | aftertreatment | Открыть |
| B100511 | medium | Output short-circuit to GND. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100512 | medium | Output short-circuit to BAT+. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100513 | medium | Open circuit conditions detected on output pin. Threshold for open circuit detection: <100uA @ 0,8V. | Volvo TRUCKCIOM | power_supply | Открыть |
| B100516 | high | Feedback voltage measured on the output is lower defined threshold (configurable). Threshold: <(0.1*VBAT)-0.2. | Volvo TRUCKCIOM | aftertreatment | Открыть |
| B100517 | high | Feedback voltage measured on the output is higher defined threshold (configurable). Threshold: <0.05*VBAT. | Volvo TRUCKCIOM | aftertreatment | Открыть |
| B150216 | high | LIN slave measures power supply voltage lower than 7.5V (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150217 | high | LIN slave measures power supply voltage higher than 18.5V (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150244 | high | LIN slave RAM check fail (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150245 | high | LIN slave ROM check fail (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150246 | high | LIN slave flash corruption detected during writing of calibration data (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150294 | high | LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected; | Volvo TRUCKCIOM | can_communication | Открыть |
| B150316 | high | LIN slave measures power supply voltage lower than 7.5V (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150317 | high | LIN slave measures power supply voltage higher than 18.5V (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150344 | high | LIN slave RAM check fail (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150345 | high | LIN slave ROM check fail (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150346 | high | LIN slave flash corruption detected during writing of calibration data (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150394 | high | LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected; | Volvo TRUCKCIOM | can_communication | Открыть |
| B150416 | high | LIN slave measures power supply voltage lower than 8.0V (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150417 | high | LIN slave measures power supply voltage higher than 18.0V (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150446 | high | LIN slave flash corruption detected during writing of calibration data (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150463 | high | Signal from LIN slave stay in active state too long time: depends of switch. See Proposed Workshop Action for more information. | Volvo TRUCKCIOM | can_communication | Открыть |
| B150494 | high | LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected; | Volvo TRUCKCIOM | can_communication | Открыть |
| B150516 | high | LIN slave measures power supply voltage lower than 7.5V (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150517 | high | LIN slave measures power supply voltage higher than 18.5V (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150544 | high | LIN slave RAM check fail (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150545 | high | LIN slave ROM check fail (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150546 | high | LIN slave flash corruption detected during writing of calibration data (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150549 | high | Push button scan is not configured correctly (FCI reception). | Volvo TRUCKCIOM | sensor_actuator | Открыть |
| B150594 | high | LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected; | Volvo TRUCKCIOM | can_communication | Открыть |
| B150616 | high | LIN slave measures power supply voltage lower than 7.5V (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |
| B150617 | high | LIN slave measures power supply voltage higher than 18.5V (FCI reception). | Volvo TRUCKCIOM | can_communication | Открыть |