| 0016 | SPN 22high | Engine speed detected by engine speed sensor, but no signal from camshaft position sensor | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0070 | SPN 112high | Temperature sensor before compressor low or ambient temperature sensor high | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0071 | SPN 113high | Temperature sensor before compressor high or ambient temperature sensor low | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0087 | SPN 135high | Fuel pressure in the accumulator | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0088 | SPN 136high | Fuel pressure in the accumulator | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0094 | SPN 148high | Fuel pressure in the accumulator | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0096 | SPN 150high | Boost temp sensor (T_BOOST), faulty | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0097 | SPN 151high | Boost temp sensor (T_BOOST), short circuit to ground | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0098 | SPN 152high | Boost temp sensor (T_BOOST), short circuit to +24V or open load | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0100 | SPN 256high | Mass flow sensor (DM_EGR), stuck | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0101 | SPN 257high | Mass flow sensor (DM_EGR), faulty | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0102 | SPN 258high | Mass flow sensor (DM_EGR), short circuit to ground or open load | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0103 | SPN 259high | Mass flow sensor (DM_EGR), short circuit to +24V | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0107 | SPN 263high | Boost press sensor (P_BOOST), short circuit to ground or open load | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0108 | SPN 264high | Boost press sensor (P_BOOST), short circuit to +24V | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0111 | SPN 273high | Inlet air mass flow temp, faulty | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0112 | SPN 274medium | Inlet air mass flow temp, short circuit to ground | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0113 | SPN 275medium | Inlet air mass flow temp, short circuit to battery or open load | ScaniaEMS S8/EMD1 | power_supply | Открыть |
| 0115 | SPN 277medium | Engine temperature sensor stuck | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0116 | SPN 278high | Engine temp sensor 1 (T_ENG1), faulty | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0117 | SPN 279medium | Engine temp sensor 1 (T_ENG1), short circuit to ground | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0118 | SPN 280medium | Engine temp sensor 1 (T_ENG1), short circuit to battery or open load | ScaniaEMS S8/EMD1 | power_supply | Открыть |
| 0128 | SPN 296high | Coolant Temperature Below Thermostat Regulating Temperature | ScaniaEMS S8/EMD1 | cooling | Открыть |
| 0191 | SPN 401high | Fuel Rail press sensor (P_RAIL), faulty | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0192 | SPN 402high | Fuel Rail press sensor (P_RAIL), short circuit to ground | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0193 | SPN 403high | Fuel Rail press sensor (P_RAIL), short circuit to +24V or open load | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0201 | SPN 513high | Injector cyl. 1 cable/injector open load | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0202 | SPN 514high | Injector cyl. 2 cable/injector open load | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0203 | SPN 515high | Injector cyl. 3 cable/injector open load | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0204 | SPN 516high | Injector cyl. 4 cable/injector open load. | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0205 | SPN 517high | Injector cyl. 5 cable/injector open load | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0206 | SPN 518high | Injector cyl. 6 cable/injector open load | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0207 | SPN 519high | Injector cyl. 7 cable/injector open load | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0208 | SPN 520high | Injector cyl. 8 cable/injector open load | ScaniaEMS S8/EMD1 | fuel | Открыть |
| 0219 | SPN 537high | Engine Overspeed, Value to high | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0234 | SPN 564high | Boost pressure higher than reference | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0263 | SPN 611high | Cylinder 1 balancing min or max. | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0266 | SPN 614high | Cylinder 2 balancing min or max | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0269 | SPN 617high | Cylinder 3 balancing min or max | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0272 | SPN 626high | Cylinder 4 balancing min or max | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0275 | SPN 629high | Cylinder 5 balancing min or max | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0278 | SPN 632high | Cylinder 6 balancing min or max | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0281 | SPN 641high | Cylinder 7 balancing min or max | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0284 | SPN 644high | Cylinder 8 balancing min or max | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0299 | SPN 665high | Boost pressure lower than reference | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |
| 0340 | SPN 832high | Camshaft Position Sensor, Open Circuit. | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0341 | SPN 833high | Camshaft Pulse Pattern, Gap or Sync Error or other fault. | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0342 | SPN 834high | Camshaft position sensor, short circuit to ground | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0343 | SPN 835high | Camshaft position sensor, short circuit to battery | ScaniaEMS S8/EMD1 | sensor_actuator | Открыть |
| 0400 | SPN 1024high | Egr system faulty | ScaniaEMS S8/EMD1 | air_egr_turbo | Открыть |